Page Loading - Please Wait...
Water-Year Summary for Site 07239450
10/01/2022 - 09/30/2023: records good.
Some regulation by Canton Lake (station 07238500).
Quality of data for other periods can be obtained by contacting the Oklahoma-Texas Water Science Center.
WATER TEMPERATURE: Water quality data only was collected between 1974 - 1975. The site was set up for stream gaging and water quality monitoring in October 1988 to current year.
SPECIFIC CONDUCTANCE: Water quality data only was collected between 1974 - 1975. The site was set up for stream gaging and water quality monitoring in October 1988 to current year.
pH: Water quality data only was collected between 1974 - 1975. The site was set up for stream gaging and water quality monitoring in October 1988 to current year.
DISSOLVED OXYGEN: Water quality data only was collected between 1974 - 1975. The site was set up for stream gaging and water quality monitoring in October 1988 to current year.
Accuracy rating of the record for the 2023 Water Year:
WATER TEMPERATURE: Excellent; No fouling or calibration corrections were applied per USGS water temperature policy. Minimal data loss occurred. This sensor was NIST checked on a quarterly basis, and two cross section surveys were completed throughout the year to confirm stream mixing conditions and sonde placement.
SPECIFIC CONDUCTIVITY: Good; Fouling and calibration drift corrections were applied throughout the year. Some data loss occurred due to equipment malfunctions, data deletions, and site visits. Two cross section surveys were completed throughout this year to confirm stream mixing conditions and sonde placement.
pH: Good; Fouling and calibration drift corrections were applied throughout the year while some data gaps occurred due to equipment malfunctions, data deletions, and site visits. Two cross section surveys were completed throughout this year to confirm stream mixing conditions and sonde placement.
DISSOLVED OXYGEN: Good; Fouling and calibration drift corrections were applied throughout the year. Some data gaps occurred due to equipment malfunctions, data deletions, and site visits. Two cross section surveys were completed throughout this year to confirm stream mixing conditions and sonde placement.
WATER TEMPERATURE:
Maximum 39.0°C on 7/2/1990
Minimum -1.41°C on 03/05/2019
SPECIFIC CONDUCTANCE:
Maximum 2451 µS/cm on 8/15/2022
Minimum 85 µS/cm on 8/17/1996
pH:
Maximum 9.47 units on 8/10/2022
Minimum 6.4 units on 6/19/2013 & 4/22/2014-4/23/2014
DISSOLVED OXYGEN:
Maximum 20.7 mg/l on 7/19/2006
Minimum 0.7 mg/l on 8/28/2014