Water-Year Summary for Site 06796500
Seasonal deployment of a continuous water-quality monitor. Measured parameters include water temperature, specific conductance, dissolved oxygen, turbidity, and nitrate. Turbidity measurements conform to ISO 7027 standards. Dissolved oxygen measurements were collected using a luminescent sensor. Nitrate measurements were collected using a Hach Nitratax sensor with 2 mm wavelength sensing.
YSI Exo probes used at this site include:
Wiped Conductance probe (USGS Parameter Code 00095, method code SC001).
Dissolved Oxygen probe (USGS Parameter Code 00300, method code LUMIN).
Turbidity probe (USGS Parameter Code 63680, YSI Exo2-method code TS213).
These extremes may have been exceeded during non-measured portions of the record.
WATER TEMPERATURES: Maximum, 37.6°C, July 28, 2023; minimum, 0.0°C,multiple occurrences
SPECIFIC CONDUCTANCE: Maximum, 865 uS/cm, May 23, 2016; minimum, 187 uS/cm, August 7, 2017.
DISSOLVED OXYGEN: Maximum, 15.9 mg/L, April 30, 2020; minimum, 4.0 mg/L, July 22, 2017.
TURBIDITY: 2016 to the present, a YSI EXO was used. (USGS Parameter Code 63680, method code TS213).
Maximum, 1960 FNU, May 01, 2022; minimum, 7.4 FNU, April 21, 2022.